Effluent

MEE or MVR: choosing the evaporator for a ZLD plant

An MEE runs on steam and an MVR on electricity. Steam economy, power per cubic metre, boiling point rise, scale and corrosion, and how to choose between them.

After reverse osmosis, the evaporator does the heavy lifting in a ZLD plant: it boils off most of the water RO could not recover. There are two ways to pay for that boiling. A multiple-effect evaporator (MEE) uses steam and re-uses its heat several times. A mechanical vapour recompression evaporator (MVR) uses electricity, compressing its own vapour so that it can heat the brine again.

How an MEE saves steam

Boiling off a kilogram of water takes roughly the heat in a kilogram of steam. A single-effect evaporator evaporates about 0.75 to 0.95 kg of water for each kg of steam. In an MEE, the vapour boiled off in the first effect heats the second effect, which runs at a lower pressure so its brine boils at a lower temperature, and so on down the line. Each effect re-uses the heat once more:

EffectsTypical steam economy, kg of water per kg of steamSteam to evaporate 22 m³ a day
3about 2.58.8 t a day
4about 3.26.9 t a day
5about 3.95.6 t a day

More effects save steam but cost more equipment, and every effect needs its own temperature drop. The number of effects is limited by the steam pressure available at the top and the cooling water at the bottom, less the boiling point rise of the brine in every effect. The vapour from the last effect is condensed against cooling water, so an MEE needs a cooling tower. A thermal vapour recompressor fitted to an MEE saves roughly as much steam as one more effect.

How an MVR saves energy

An MVR compresses the vapour it boils off. That raises the vapour's pressure, and so its condensing temperature, by a few degrees, enough for it to heat the same evaporator. Apart from start-up it needs no steam, and very little cooling water. Its energy is the fan or compressor power: published figures for brine concentrators run from about 15 to over 20 kWh per cubic metre of feed, which is more per cubic metre actually evaporated. At 30 kWh per cubic metre evaporated, the same 22 m³ a day takes about 660 kWh a day.

Comparing running cost

The comparison is your steam price against your power price. In our worked ZLD example, with steam at ₹2,500 a tonne and power at ₹8 a kWh, the 4-effect MEE spends about ₹17,000 a day on steam and the MVR about ₹5,300 a day on power. Those prices are only examples: the calculator takes yours. An MVR usually costs more to buy, and earns the difference back in running cost over the years.

Boiling point rise: where MVR stops

Dissolved salt raises the boiling point of a brine, and the rise grows steeply as the brine concentrates. An MVR fan or compressor can add only a limited temperature lift, so as the boiling point rise grows its power climbs, and in the end it cannot keep up. Calcium chloride is the extreme case: a saturated solution boils about 59 °C above water at atmospheric pressure. That is why an MVR usually takes a brine part of the way, and steam-heated effects, a forced circulation crystallizer or the ATFD finish it.

Scale and corrosion

  • Scale. As the brine concentrates, calcium sulphate, silica and carbonates come out of solution on the hot tubes. Forced circulation, seeding the brine with crystals so salts grow on the seeds instead of the tubes, and regular cleaning keep heat transfer up.
  • Corrosion. Hot chloride brine attacks ordinary stainless steels. Parts that touch it are made in materials chosen for the brine and the temperature.
  • Foaming and carry-over. Oil and organics from degreasing make brines foam and spoil the condensate. Remove them in the ETP, not in the evaporator.
AspectMEEMVR
EnergySteam, with cooling waterElectricity
Running costHigher where steam is costlyLower where power is reasonable
Capital costLowerHigher
High boiling point riseHandles itLimited
Best fitStrong, difficult brines; plants with steam to spareLarger flows of moderate brine

Products in this article

More insights