RO before the evaporator: how far can recovery go?

Each cubic metre RO recovers is one the evaporator need not boil. What limits RO recovery on neutralised pickling effluent, and how pretreatment protects it.

Reverse osmosis is the cheapest way to take clean water out of salty water: a pump pushes the water through a membrane, instead of boiling it. In a ZLD plant, every cubic metre RO recovers is a cubic metre the evaporator does not have to boil. Raising RO recovery is usually the biggest saving in the plant, until one of its limits is reached.

Limit 1: osmotic pressure

To push water out of a brine, the pump has to beat the brine's osmotic pressure, which rises with its salt content: roughly 0.7 to 0.8 bar for every gram per litre of common salt. As RO takes water out, the salt left behind concentrates. At 75 per cent recovery the reject is about four times as strong as the feed. RO sets a ceiling on how strong the reject can get, and that ceiling sets the highest recovery. If the reject may reach 60,000 mg/L, a feed of 12,000 mg/L allows at most 80 per cent recovery, and a feed of 30,000 mg/L only 50 per cent.

Limit 2: scale

As the reject concentrates, salts that dissolve only sparingly reach saturation and can precipitate on the membranes: calcium sulphate, calcium carbonate and silica, and calcium fluoride where fluoride is present. Antiscalant dosing, pH control and softening push this limit back. Neutralised hydrochloric acid effluent, rich in chloride and poor in sulphate, is kinder to RO than sulphuric acid effluent, where lime leaves the water saturated with calcium sulphate.

Limit 3: fouling

Iron is the classic fouler in pickling effluent. Iron left dissolved after the clarifier oxidises on the membrane and coats it. Oil from degreasing, fine suspended solids and biological growth do the same. Pretreatment is there to protect the membranes:

  • Thorough oxidation and settling in the ETP, so the iron leaves as sludge, not on the membrane.
  • Sand and carbon filters, or ultrafiltration where the water is difficult, then cartridge filters before the high-pressure pumps.
  • Softening where hardness would scale.
  • Antiscalant dosing, and cleaning in place on a schedule set by the pressure drop and the permeate flow.

Recovery and the evaporator

On the 90 m³ a day example in our ZLD design article, RO at 75 per cent sends about 24 m³ a day of reject to the evaporator. At 60 per cent it would send about 38 m³; at 85 per cent, if the reject limit allowed it, about 14 m³. With a 4-effect MEE that is the difference between about 11.4, 6.9 and 3.9 t of steam a day. The price of high recovery is pressure: the estimated feed pressure rises from about 27 bar at 60 per cent to about 63 bar at 85 per cent.

RO recoveryReject to the evaporatorReject strengthMEE steam, 4 effects
60 %about 38 m³ a dayabout 28,000 mg/L11.4 t a day
75 %about 24 m³ a dayabout 45,000 mg/L6.9 t a day
85 %about 14 m³ a dayabout 74,000 mg/L3.9 t a day

Permeate quality

RO permeate is low in salt but not free of it. It usually suits rinse water, cooling tower make-up and general plant use. Where boiler feed quality is needed, a second RO pass or ion exchange polishes it further.