Electro-galvanizing rectifier calculator
From wire size, strands, line speed and zinc coating: the plating current, the current density on the wire, the rectifier rating and the zinc used.
What you enter
- Wire Ø, typical 2.5 mm
- Strands, typical 24
- Line speed, typical 40 m/min
- Zinc coating, typical 30 g/m²
Under Advanced, 5 more inputs for a closer answer, each set to a typical value until you change it: Current efficiency 95 %; Plating length 30 m; Plating cells 4; Cell voltage 9 V; Running hours 20 h/day.
What it works out
- Plating current
- Current density
- Rectifiers
- Zinc
- Coating thickness
- Wire plated
- Zinc per tonne of wire
- Current per cell
- DC power
- Supply needed (all rectifiers)
- Wire area in the bath
How it works
Faraday’s law with 1.2195 g of zinc per ampere-hour. Rectifier voltage must cover the bath, contacts and busbars; choose the anode-to-wire gap and contact rolls with SHIVAS. Water-cooled thyristor or switch-mode rectifiers in standard ratings.
Each size it picks (a motor, burner, rectifier or fan) is the next standard size above the calculated need. Choose an extra margin of 10, 20 or 30 % and it is added to the need before the size is picked; nothing else is added.
The answer is a first sizing from typical values, and every input can be changed. Press Ask our engineer to check this under the results and SHIVAS replies with a checked sizing and a proposal.
The equipment it sizes
The same calculator is on each of these pages.
From our engineers
- Electro-galvanizing wire: current, coating and the rectifierIn electro-galvanizing, the coating is bought as electricity. How to work out the current a line needs, why current density matters, and how the plating ce
- Testing the zinc on galvanized wire: coating mass, uniformity and adherenceHow galvanized wire coatings are tested: strip and weigh, with the formula and a worked example, the Preece dip for uniformity, and wrapping for adherence.
Other calculators
- Galvanizing plant calculatorKettle, furnace, zinc, fuel and cost per tonne from your steel and tonnage.
- Wire drawingPasses, die sequence, block speeds, kW and output
- High-velocity burner kWFiring rate, burners, wall heat flux, fuel
- ETP and ZLD plantNeutraliser, sludge, RO, MEE or MVR, ATFD, steam and power
- Coating thickness checkISO 1461 minimums, g/m², zinc per tonne
- Inline phosphating lineBath length, coating time, phosphate and output
- Fume scrubber + blowerAir flow, tower size, packing, pump, blower kW and HP
- Pickling acidAcid use, spent acid, tank charge
- Spent acid neutralisationLime, filter cake and dissolved salt
- Bag filterCloth area, bags, housing, fan kW and HP
- Fan / blower motorAir power, shaft kW, motor kW and HP
- FRP profile weight and deflectionkg per metre, steel comparison, beam check