Burner kW calculator for galvanizing furnaces

From your largest article and the tonnage: the kettle it needs, the heat the furnace has to put into the zinc, the firing rate, how many high-velocity burners of what size, the heat flux on the kettle wall and the fuel per hour.

What you enter

Under Advanced, 8 more inputs for a closer answer, each set to a typical value until you change it: Kettle length from the article; Kettle width from the article; Kettle depth from the article; Steel temperature into the zinc 60 °C; Zinc picked up 60 kg/t; Bath surface loss while dipping 9 kW/m²; Furnace available heat 45 %; Burners auto.

What it works out

How it works

Steel cp 0.49 kJ/kg·K; zinc heated from ingot and melted (112 kJ/kg). Furnace casing loss ≈ 0.45 kW/m². Available heat depends on excess air and flue temperature; a recuperator raises it. SHIVAS sets burner positions and firing so the wall is heated evenly.

Each size it picks (a motor, burner, rectifier or fan) is the next standard size above the calculated need. Choose an extra margin of 10, 20 or 30 % and it is added to the need before the size is picked; nothing else is added.

The answer is a first sizing from typical values, and every input can be changed. Press Ask our engineer to check this under the results and SHIVAS replies with a checked sizing and a proposal.

The equipment it sizes

The same calculator is on each of these pages.

From our engineers

Other calculators

All calculators on one page →