Galvanized coating thickness check
Check a hot-dip galvanized coating against the ISO 1461 minimums for your steel. Enter the mean of your gauge readings and the lowest local value: see whether each one passes, the coating mass in g/m² and the zinc the coating puts on each tonne of steel.
What you enter
- Article, one of: Steel sections and plate; Castings; Centrifuged: bolts, studs and nuts; Centrifuged: other small parts
- Steel thickness (thread Ø for bolts), typical 8 mm
- Mean of all readings, typical 95 µm
- Lowest local value, typical 78 µm
Under Advanced, 1 more inputs for a closer answer, each set to a typical value until you change it: Surface per tonne from the thickness.
What it works out
- Mean
- Lowest local
- Coating mass
- Zinc on the steel
- ISO 1461 class
- Minimum local
- Minimum mean
- Zinc at the minimum mean
- Zinc above the minimum
How it works
Minimums from ISO 1461 for articles that are not centrifuged and for centrifuged ones, with coating mass at the standard's nominal 7.2 g/m² per µm. A local value is the average of the gauge readings in one reference area; the mean is the average over all the reference areas on the article or sample. Surface per tonne is estimated from the thickness (flat steel 254.8 ÷ t, bolts 509.6 ÷ Ø); zinc lost to dross and ash comes on top. If your order names ASTM A123 or IS 4759, check against that standard's own table.
The answer is a first sizing from typical values, and every input can be changed. Press Ask our engineer to check this under the results and SHIVAS replies with a checked sizing and a proposal.
The equipment it sizes
The same calculator is on each of these pages.
- Zinc kettleGalvanizing kettles in kettle-grade low-silicon steel, sized to your work and built to carry hundreds of tonnes of zinc at 450 °C.
- Turnkey galvanizing plantOne team from the first tonnage study to the first dipped load: process, layout, equipment, erection and commissioning.
- Spin galvanizing plantAutomatic spin galvanizing for bolts, nuts and washers: dipped in baskets, spun over the bath, clean threads every time.
From our engineers
- Measuring galvanized coating thickness: gauges, readings and ISO 1461A gauge reading is easy to take and easy to get wrong. How to check the gauge, where to measure, and how to judge local and mean values against ISO 1461.
- How long will galvanizing last? Corrosivity, thickness and coating lifeCoating life is zinc thickness divided by how fast zinc corrodes on site. How to estimate it from the ISO 9223 categories, with examples, and what changes it.
- Silicon in steel and the Sandelin effectWhy some steel comes out of the zinc thick, grey and brittle, and what galvanizers and their customers can do about it.
- Where your zinc really goes: coating, dross and ashZinc is most of the running cost of a galvanizing plant. Only part of it ends up on the steel. Here is where the rest goes, and what you can do about each
- Spin galvanizing for fasteners: why threads need a centrifugeBolts, nuts and washers cannot be drained like structural steel. How spin galvanizing works and how to plan a spin line.
- Dull grey, thick and flaking coatingsWhy some steel comes out heavy and grey, when that is only a matter of looks, and when it turns into a real problem.
Other calculators
- Galvanizing plant calculatorKettle, furnace, zinc, fuel and cost per tonne from your steel and tonnage.
- Electro-galvanizing rectifierCurrent, current density and rectifier size
- Wire drawingPasses, die sequence, block speeds, kW and output
- High-velocity burner kWFiring rate, burners, wall heat flux, fuel
- ETP and ZLD plantNeutraliser, sludge, RO, MEE or MVR, ATFD, steam and power
- Inline phosphating lineBath length, coating time, phosphate and output
- Fume scrubber + blowerAir flow, tower size, packing, pump, blower kW and HP
- Pickling acidAcid use, spent acid, tank charge
- Spent acid neutralisationLime, filter cake and dissolved salt
- Bag filterCloth area, bags, housing, fan kW and HP
- Fan / blower motorAir power, shaft kW, motor kW and HP
- FRP profile weight and deflectionkg per metre, steel comparison, beam check