SHIVAS Technology · Galvanizing

Acid enclosed room

A closed pretreatment room with its own extraction and a crane slot, so acid fume stays away from steelwork, cranes and people.

  • Closed pretreatment
  • Crane slot
  • Negative pressure
  • Corrosion-proof build
Acid enclosed room1 photo
Negative pressurefume drawn in, not out
Crane slotwork moves in and out without opening walls
Corrosion-proofcladding and structure built for HCl

Overview

Open pickling tanks release hydrochloric acid fume that corrodes the whole shed: roof, cranes, electrics and the steel waiting to be galvanized. An acid enclosed room puts all the acid baths inside a closed structure held under slight negative pressure and exhausted through a scrubber.

Work is carried through a slot in the roof by the crane, with doors or curtains at the ends. Structure, cladding, lighting and doors are chosen to survive inside; the extraction is sized for the room volume and the tank surfaces.

Why it pays

Protects the plant

Cranes and buildings outside the room stay dry of acid.

Safer work

Operators outside the acid atmosphere.

Compliance

All fume goes through a scrubber before the stack.

Lower heat loss

Heated baths stay warmer inside.

Technical specification

Typical ranges. Every unit is sized to your duty; the offer carries the exact figures.

StructureCoated steel or FRP-protected frame
CladdingFRP / PP or coated sheet
ExtractionRoom or combined lip and room to a wet scrubber
AccessCrane slot with brush seal, end doors
PressureSlightly negative
Line drawing

Calculator

Work it out for your own plant. Every input is a typical value you can change and the results follow as you type; send the result to us and we reply with a proposal.

Options, build and uses

Options

  • Double-line rooms
  • Integrated flux and drying zones
  • Fume monitoring

How we build it

  • Fabricated and erected by SHIVAS
  • Scrubber and fan from SHIVAS Reinplast

Who it is for

  • New galvanizing plants
  • Retrofits where acid fume is damaging the shed

Part of

Questions buyers ask

Can it be added to a running plant?

Yes, usually in phases around the existing tanks and crane.

From our engineers

Practical notes from the engineers who design and build these plants.

All articles from our engineers →

Enquiry · Acid enclosed room

Get a quote

Tell us the capacity, sizes and site. We reply with a scheme, a layout and an offer.

What we need for your quote

  • Tank line layout
  • Crane runway and hook height
  • Local emission limits

More galvanizing plant systems

See all products →